logo Aegex100M_Intrinsically_Safe_Tablet_User_Guide

CONTENTS

Warnings 3
FCC, IC, and CE NOTICES 4
IMPORTANT PRODUCT INFORMATION AND SAFETY NOTICES 5
PRODUCT WARRANTY 5
ENERGY SAVING 5
FRONT OF TABLET 6
BACK OF TABLET 8
SD & SIM PORT
VESA MOUNT
SHOULDER STRAP/ACCESSORY MOUNT
APPENDIX
TABLET POWER SUPPLY A-1
BATTERY AND BATTERY SAFETY A-2
RECYCLE A-2
Warning_Icon Open_Book_Icon

WARNINGS & NOTICES

  • Read all instructions before using this product.
  • To prevent possible hearing damage, do not listen at high volumes for long periods of time.
  • Only use Aegex approved accessories with the Aegex100M.
  • Removing the battery pack will invalidate the product’s IP67 rating and may void the warranty

AVERTISSEMENTS & AVIS

  • Lisez toutes les instructions avant d’utiliser ce produit.
  • Pour éviter d’éventuels dommages auditifs, n’écoutez pas à des volumes élevés pendant de longues périodes.
  • Utiliser des accessoires homologués Aegex avec l’Aegex100M.
  • Le retrait de la batterie invalidera l’indice de protection IP67 du produit.

In Hazardous Locations Explosive_Hazard_Icon

The Aegex100M is certified for use in various hazardous locations depending on the model number and certification marking printed on the product.

dans une zone À risque d’explosion Explosive_Hazard_Icon

L’Aegex100M est certifié pour une utilisation dans des zones à risque d’explosion en fonction du numéro de modèle et du marquage de certification sur le produit.

FCC Statements

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

§15.105 Information to the user.

For a Class A digital device or peripheral, the instructions furnished the user shall include the following or similar statement, placed in a prominent location in the text of the manual:

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Industry Canada Notice: Canada Only

This device complies with Industry Canada RF radiation exposure limits set forth for general population (uncontrolled exposure). This device must not be collocated or operating in conjunction with any other antenna or transmitter. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage es susceptible d’en compromettre le fonctionnement.

CE_Icon

CE Statement 3015

Aegex Technologies LLC, Flatiron Building, 84 Peachtree Street NW Atlanta, GA 30303 USA hereby declare, under its sole responsibility that the product Aegex100M Intrinsically Safe Tablet is in conformity with the relevant European Union harmonization legislation:

Important Product Information and Safety Notices

Warranties

For more information on warranty services of Aegex100M, please visit our site at this link or scan the QR code to the right https://aegex.com/support/warranty

This product is covered by a Limited Manufacturer’s Warranty and does not cover misuse of the product including but not limited to extended exposure to heat, cold, or other adverse conditions and uses.

Energy Saving

You can save energy by doing following:

Front_Tablet_Diagram Front_Tablet_Legend Back_Tablet_Diagram Back_Tablet_Legend

SD and SIM Port

SD_Guide

Do Not open MicroSD and Nano-SIM port in hazardous locations.

To insert a MicroSD card or Nano-SIM card, please read the directions below carefully. NOTE: Pay close attention to how each port slides open or closed. Failing to properly open or close either port can damage the device or disable certain functionality.

To install or replace a MicroSD card or Nano-SIM Card, remove the Port Cover in a non-hazardous area with the 000 Philips head screwdriver provided with your tablet.

The MicroSD Card slot is located on the right side under the Port Cover. To insert an MicroSD Card, open the slot by sliding it to the right, lift up the slot cover, insert the MicroSD card, close and lock the MicroSD Card in place by sliding the slot cover back to the left.

The Nano-SIM Card slot is l ocated on the left side under the Port Cover. Open the slot by sliding it left, lift up the slot cover, insert the Nano-SIM card, close and lock the Nano-SIM in place by sliding the slot cover back to the right.

VESA Mount

The Aegex100M has a standard VESA mount configuration FDMI MIS-C 75mm x 35mm. Use only M4 x 8mm screws. Other screws may damage the device and may impact its safety and certifications. VESA mounting holes are identified below.

Back_Tablet_Screw_Guide

Shoulder Strap / Accessory Mount

To attach the shoulder strap, remove the plastic caps over the screw mounting holes you wish to use. Removing these caps does not impact certification or the use of the product in hazardous areas.

Attach the shoulder strap or other approved accessories using the M5 screws provided in the locations shown below.

Shoulder_Strap_Accessory_Mount

Warning_Icon Open_Book_Icon Tablet Power Supply

Power_Input_Diagram

Warning_Icon Open_Book_Icon Battery Safety

Visually inspect battery and battery housing on a regular basis. Your rechargeable Lithium-ion battery operates on 7.2V and 2x 3450mAh, Aegex100M Battery AAEB-100-XX

Recycle

Return your used electronic units to dedicated collection points. Please note that your tablet has a Lithium-ion battery. It must be recycled separately. These batteries and/or your Aegex100M, should NOT go into household garbage or recycling bins. Follow your local jurisdiction’s rules and regulations regarding proper Lithium-ion battery disposal.

Lithium-ion batteries and devices containing these batteries should NOT go in household garbage or recycling bins. Lithium-ion batteries SHOULD be taken to separate recycling or household hazardous waste collection points.

RoHS Do_Not_Trash_Icon

Aegex_Logo
Aegex Technologies, LLC
  Flatiron Building
  84 Peachtree St NW
  Atlanta, GA 30303
  
  Aegex Technologies, LLC
  Hungarian Branch Office
  H-7632 Pécs, Tildy Zoltán u. 27/1
  
  +1 404 242 4000
  contact@aegex.com
  
© Copyright 2024 Aegex Technologies, LLC. All Rights Reserved. Aegex, Aegex Technologies and Aegex Technologies, LLC are registered trademarks of Aegex Technologies, LLC with the U.S. Patent and Trademark Office. All Aegex Technologies products, including components or features thereof and/or associated software, are protected by copyright, international treaties and patents and patents pending. Some of these rights are reflected in registrations, pending applications, common law rights, or by act of law, regulations, and treaties. All other brands, product names, company names, trademarks and service marks are the property of their respective owners.